• ENM5072-250.jpg

Enmatic 5000 Series Wall Mounted Sensor Activated Wave-On Wave-Off - Mains Powered

Key features

  • Proven infra-red sensor technology
  • No touch operation is more hygienic and reduces the risk of hand cross contamination
  • Safety auto shut-off after 45secs (longer periods avaialble on request)
  • 24V AC mains power. Includes Power Pack, Solenoid and 1.8m Connection Cables
  • Supplied complete including 4 fixing screws
  • WELS 6 Star (6lpm) supplied as standard, also available in 4 Star (8 lpm) and 3 Star (9.5lpm) WELS rating
  • Products

    Order code Enmatic 5000 Series Wall Mounted Sensor Activated Wave-On Wave-Off - Mains Powered
    ENM5072-250
    250mm Spout - 235 to centre of outlet - 45 second timed out (if not waved off)
  • Inlet Connection 15mm (1/2") BSP
    Minimum-Maximum Working Pressure (AS/NZS 3500)* 50-500kPa*
    Maximum Static Pressure 800kPa
    Maximum Temperature 70 C*
    Time Flow Specifications ENM5071 Adjustable flow time to 3, 6, 9 or 12 seconds. (Default 6 seconds)
    Wave-On Wave-Off Specifications ENM5072 45 seconds maximum run time if not waved off by user.
    Power Supply 24V AC
    Sensor Range Approx. 170mm
    *Enware products are to be installed in accordance with AS/NZS3500. NOTE: Enware Australia advises:1. Due to ongoing Research and Development, specifications may change without notice. 2. Component specifications may change on some export models.